The air quality meter is the ideal measuring device to check the climatic conditions in, for example, warehouses, production halls or greenhouses. The air quality meter can measure the ambient temperature and humidity. Temperatures between -20 ... 60 °C (-4 ... 140 °F) can be measured reliably and quickly by the air quality meter. In addition, the dew point and wet bulb temperature is calculated and displayed by the air quality meter. In addition, any type K thermocouple can be connected to the air quality meter in a temperature range of -100 ... 1372 °C (-148 ... 2501 °F). As soon as the connected thermocouple has been recognized, the temperature display automatically switches from the air quality meter to the thermocouple.
Measured values can be recorded with the data logger function of the air quality meter. The large memory of 32,000 measuring points in the air quality meter allows recording of measured values over a long period of time. After data logging, all logged measuring points can be read out and analyzed via the micro-USB interface of the air quality meter and the free software. The data logged by the air quality meter can be exported in CSV file format for further processing.
A 3.7 V Li-ion battery is installed in the air quality meter to enable mobile use. This battery can be recharged via the micro-USB interface on the air quality meter.
Features:
- Measuring range -20 ... 60 °C / -4 ... 140 °F
- Temperature, humidity, dew point
- Backlit LC display
- Micro USB interface
- Rechargeable battery
- Data memory for 32,000 readings
- Wet bulb temperature
- Optionally with ISO calibration certificate
What's In The Box:
- 1 x Air quality meter PCE-THD 50
- 1 x Type K thermocouple
- 1 x USB cable
- 1 x PC software
- 1 x Instruction manual
Specifications:
Air temperature |
Measuring range |
-20 … 60 °C(-4 … 140 °F) |
Resolution |
0.01 °C/°F |
Accuracy |
±0.5 °C @ 0 … 45 °C,±1.0 °C |
|
in remaining range |
|
±1.0 °F @ 32 … 113 °F,±2.0 °F |
|
in remaining range |
Measuring rate |
3 Hz |
|
|
Relative humidity |
Measuring range |
0 … 100 % RH |
Resolution |
0.1 % RH |
Accuracy |
±2.2 % RH (10 … 90 % RH) |
|
@ 23 °C (73.4 °F) |
|
±3.2 % RH (<10,>90 % RH) |
|
@23 °C (73.4 °F) |
Response time |
<10 s (90 % RH, 25 °C (77 °F), with no wind) |
|
|
Thermoelement |
Sensor type |
Thermoelement Type K |
Measuring range |
-100 … 1372 °C(-148 … 2501 °F) |
Resolution |
0.01 °C/°F, 0.1 °C/°F, 1 °C/°F |
Accuracy |
±(1 % ±1 °C) |
|
|
Calculated values |
|
Wet bulb temperature |
-20 … 60 °C (-4 … 140 °F) |
Dew point temperature |
-50 … 60 °C (-58 … 140 °F) |
|
|
Further specifications |
Internal memory |
99 measuring points |
|
(redundant, only readable on the measuring device) |
|
32,000 measuring points |
|
(only readable on the PC) |
Power supply |
3.7 V Li-ion battery |
Operating conditions |
0 … 40 °C (32 … 104 °F) <80 % RH, |
|
non-condensing |
Storage conditions |
-10 … 60 °C (14 … 140 °F) <80 % RH, |
|
non-condensing |
Dimensions |
162 mm x 88 mm x 32 mm / 6.3 x 3.4 x 1.2" |
Weight |
248 g / 8.74 oz |