Mold Inspection Consulting and Remediation Organization
Since 2006
close menu

Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.

The Triplett Model CM1000 True RMS Clampmeter can measure AC current up to 1000A without breaking the circuit by clamping around a single conductor.

More info

Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.
Roll over image to zoom Click image to expand
  • Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.
  • Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.
  • Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.
  • Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.
  • Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.
  • Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.
  • Triplett CM1000-NIST CM1000 1000A True RMS AC Clamp Meter w/Cert of Traceability to N.I.S.T.

The Triplett Model CM1000 True RMS Clampmeter can measure AC current up to 1000A without breaking the circuit by clamping around a single conductor. This saves time and the circuit will not be damaged. True RMS provides better accuracy when measuring non-sinusoidal or noisy waveforms. Additional measurements include Resistance, Capacitance, Frequency, Temperature, Diode Test, and Continuity. Measurements can read on the 6000 count backlit LCD. It has an Inrush current function that captures the instantaneous surge (inrush) current when power equipment is turned on. Features include: Lo Z (impedance) mode for identifying ghost voltages, Low Pass FIlter (LPF) for filtering frequency and harmonic interference when measuring variable frequency drives, Peak voltage capture with min/max, NCV Detector with LED, Relative/DC zero function, Auto power off, and a built-in flashlight. Data Hold freezes the display for easy viewing. CAT IV-600V safety category. cETLus listed. Includes Certificate of Traceability to N.I.S.T., 3 AAA batteries, test leads, Type K thermocouple probe, and carrying case. 1-year warranty.

Features:

  • True RMS provides better accuracy when measuring non-sinusoidal or noisy waveforms
  • Captures the instantaneous surge (inrush) current when power equipment is turned on
  • 1.4" (36mm) clamp jaw opening
  • Built-in Non-Contact Voltage Detector with LED
  • Low Pass Filter (LPF) for filtering frequency and harmonic interference when measuring variable frequency drives
  • Lo Z (impedance) mode for identifying ghost voltages
  • Peak voltage measurement with Min/Max
  • Data Hold freezes the display and Relative Mode for making comparisons to a stored reference value
  • Auto power off with disable and Built-in Flashlight
  • cETLus listed

Includes: Includes Certificate of Traceability to N.I.S.T., test leads, Type K thermocouple bead probe, 3 AAA batteries, and carrying case

Battery Type: (3) AAA batteries

Specifications
CM1000
True RMS·
Display counts6000 count
AC Current1000A
ACA Accuracy±2.8%
DC Current
AC/DC Voltage1000V
Resistance60MΩ
Temperature-4 to 1832°F (-20 to 1000°C)
Capacitance100mF
Frequency100kHz
Duty Cycle10.0 to 90.0%
Continuity<50Ω
Lo Pass Filter (LPF)Yes
LoZ ModeYes
NCV Detector>90V
Inrush Current100ms
Safety CategoryCAT IV-600V
Dimensions9.9 x 3.2 x 1.7" (249 x 81.5 x 42.2mm)
Weight11.3oz (320g)

Datasheet: https://www.files.triplett.com/datasheet/cm1000.pdf